hubble: move the UI listener to 8084 — 8082 is taken on rpi

Cilium binds every Gateway listener on 0.0.0.0 on EVERY gateway node, and the Pi
still runs leftover Docker site containers: handyman-site holds 127.0.0.1:8082
and its nginx holds 127.0.0.1:8083 (a 127.0.0.1 bind still blocks a 0.0.0.0
one). Binding 8082 there made xDS reject the listener on rpi
("cannot bind '0.0.0.0:8082': Address already in use" at ~2/s) and restarted
cilium-envoy on the node that fronts the public ingress — the UI worked or not
depending on which node answered.

8084 measured free on both gateway nodes (rpi, siriussec) before the change.
Firewall moved with it: siriussec nft dport set { 8081, 8084 }, rpi ufw trio for
8084 inserted above the LAN catch-all and the 8082 rules deleted.

URL: http://10.10.0.2:8084/ (bare IP, no /etc/hosts) — same as Grafana on 8081.
This commit is contained in:
Lance Walters 2026-10-27 00:44:32 -04:00
commit a287dc8dfa
7 changed files with 62 additions and 27 deletions

View file

@ -6,14 +6,14 @@
# Final order per port: allow 10.10.0.0/24, allow 10.244.0.0/16, deny the rest.
#
# Ports: 8081 = Grafana (`internal` Gateway listener http-internal),
# 8082 = Hubble UI (`internal` Gateway listener hubble-ui).
# 8084 = Hubble UI (`internal` Gateway listener hubble-ui).
# Add a new internal listener port to PORTS; the loop is idempotent, so
# re-running after a port is already firewalled only adds what is missing.
#
# Run as root on rpi (192.168.1.125).
set -euo pipefail
PORTS="${PORTS:-8081 8082}"
PORTS="${PORTS:-8081 8084}"
for port in $PORTS; do
if ufw status | grep -q "${port}/tcp"; then