monitoring: replace the dead kubelet_volume_stats alerts with runner-scoped disk rules

kubelet_volume_stats_* was an ALPHA metric set served from kubelet's
/metrics/volumes endpoint; that endpoint returns 404 on every node of this
cluster (kubelet v1.36.4 — upstream loss in 1.34, kubernetes#133847), and
/metrics carries no volume-stats series. RunnerDindPvcHighWatermark and
RunnerDindPvcCritical therefore could never fire while showing as healthy.

Per-PVC bytes are not measurable here and no scrape config can change that,
so the pair is replaced by RunnerDindDiskHighWatermark (80%) and
RunnerDindDiskCritical (90%): root-filesystem usage on nodes that actually
run a forgejo-runner pod, which is the filesystem holding the dind data-root
under /opt/local-path-provisioner. New arm64 dind PVCs are covered as soon
as their runner is scheduled; nodes without runners (linode) do not
duplicate the generic disk-capacity group.

Also corrects the cause in docs, the dashboard notes and the prune CronJob
comment (it is not a hostPath quirk, the endpoint is gone).
This commit is contained in:
Lance Walters 2026-10-27 02:05:57 -04:00
commit e572f84b0b
8 changed files with 145 additions and 80 deletions

View file

@ -29,7 +29,8 @@
# Named volumes are NEVER pruned (docker volume prune is forbidden): they hold
# the shared CI caches (onionwire-target-ci, the Android SDK/Gradle/registry
# volumes). Their sizes are printed every run and their growth is covered by
# the `RunnerDindPvc*` / `NodeFilesystemFillingUp` alerts.
# the `RunnerDindDisk*` / `NodeFilesystemFillingUp` alerts (per-PVC bytes are
# not exported by kubelet 1.34+, so those alerts are node-filesystem scoped).
apiVersion: v1
kind: ServiceAccount
metadata:

View file

@ -418,18 +418,23 @@ went `Pending` for days. What exists today (all live, all GitOps):
**`docker volume prune` is forbidden** so `onionwire-target-ci` survives.
Requirement for the cutover: name the container `dind` and keep
`app: forgejo-runner` (§1.6).
2. **Alerts exist, but know their blind spot.** `monitoring/controllers/home/prune-alerts.yaml`
ships `RunnerDindPvcHighWatermark` (85 %) and `RunnerDindPvcCritical` (95 %)
on `kubelet_volume_stats_used_bytes{persistentvolumeclaim=~"forgejo-runner-.*"}`
— and the file's own comment says this kubelet exports **no**
`kubelet_volume_stats_*` series, i.e. those two will not fire for a hostPath
PV (which is what §6.1 recommends). The honest guard today is
`NodeFilesystemFillingUp` at **> 85 %** of rpi's root and
`NodeFilesystemCritical` at > 92 %: 85 % of 917 G leaves **137 G** — plenty
to act on, but only if someone is watching. **Recommended addition for card
2**: a Pi-specific rule at 70 % (`node_filesystem_avail_bytes{mountpoint="/",
instance=~"10.10.0.1:.*"} < 275e9`), because rpi now carries 240 GiB of CI
PVCs on the same filesystem as the kubelet.
2. **The alerts are node-scoped, because per-PVC bytes do not exist.** The old
`RunnerDindPvcHighWatermark` / `RunnerDindPvcCritical` pair was **deleted** —
it selected `kubelet_volume_stats_*`, which kubelet 1.34+ no longer exports at
all (`/metrics/volumes` 404s on every node here; upstream
kubernetes/kubernetes#133847), so it could never fire for *any* volume type,
hostPath or not. `monitoring/controllers/home/prune-alerts.yaml` instead ships
two complementary node-filesystem guards, both on the disk that holds the
dind data-root:
- `dind-disk-cap` → `RpiDindDataRootFillingUp` (**> 70 %** on rpi), which landed
with the arm64 cutover: 70 % of 917 G still leaves the room to run the prune
job, and a static PV does not enforce its claim;
- `forgejo-prune` → `RunnerDindDiskHighWatermark` (**> 80 %**) and
`RunnerDindDiskCritical` (**> 90 %**) on every *other* node that runs a
`forgejo-runner` pod (i.e. siriussec; `nodename!="rpi"` keeps the Pi from
being paged twice) with the runner-specific runbook.
Both sit inside `NodeFilesystemFillingUp` (**> 85 %**) / `NodeFilesystemCritical`
(**> 92 %**), which still cover every node as the backstop.
3. **A dedicated data-root per runner** (200 GiB + 40 GiB PVCs) so a runaway
cache cannot touch the 26 GB of unrelated host volumes on the same disk, and
so `docker system df -v` inside each pod attributes growth to one runner.
@ -797,7 +802,7 @@ dind Deployments.
| `homek8s/apps/base/forgejo/runner-deploy-arm64.yaml` | dind rewrite + guarded init container | |
| `homek8s/apps/base/forgejo/runner-configmap.yaml` | `arm64.toml`/`deploy-arm64.toml` (§6.2) | |
| `homek8s/apps/base/forgejo/prune-cronjob.yaml` | **no change** — it already prunes every dind by label; only the naming contract matters (`app=forgejo-runner` + a container named `dind`) | §1.6 |
| `homek8s/monitoring/controllers/home/prune-alerts.yaml` | optional: a rpi-specific 70 % node-fs rule, because the `RunnerDindPvc*` rules cannot fire for hostPath PVs | §4.4 |
| `homek8s/monitoring/controllers/home/prune-alerts.yaml` | **already done**: `RpiDindDataRootFillingUp` (rpi, 70 %) plus `RunnerDindDisk*` (80 % / 90 %, other runner nodes) | §4.4 |
| `homek8s/apps/base/forgejo/{pv,pvc}.yaml` (new) | 2 PVs, 2 PVCs, `local-static` SC | §6.1 |
| Pi `/home/sirius/websites/docker-compose.yml` | add `10.10.0.1:5000:5000` to `registry` | §8 |
@ -840,5 +845,7 @@ targets loopback and gets `Connection refused` from inside dind. Disk is not the
constraint (240 GiB of 387 GiB free, 146.5 GiB measured steady state); the
constraint is that a static PV does not enforce that 240 GiB either — the nightly
prune already reaches dind daemons by label (so it needs no change, only the
`dind` container name), but the `RunnerDindPvc*` alerts cannot fire for hostPath
PVs, so a Pi-specific 70 % node-fs rule should land with the cutover.
`dind` container name), and rpi's root filesystem is capped by
`RpiDindDataRootFillingUp` at 70 % (`dind-disk-cap` group) — per-PVC bytes are
simply not exported by kubelet 1.34+, so the filesystem is the only honest
measure.

View file

@ -414,9 +414,9 @@ kubectl -n forgejo logs job/prune-manual-<ts> -c dind-daemons # every dind da
**Two premises worth writing down, because the code depends on them** (both verified 2026-10-27):
- The build-cache *capacity* flags are a no-op on this buildx (0.20.1). `--keep-storage`, `--max-storage` (rejected: unknown flag) and `--max-used-space` all report `Total: 0B` with a cache over the cap — a 21.44 GB cache with `--max-used-space 20GB`, and a 541 MB cache with `--max-used-space 100MB`. `--filter until=` *does* reclaim (541 MB → 0 with `until=0s`), which is why the cap is enforced by walking age windows.
- `kubelet_volume_stats_used_bytes` / `_capacity_bytes` **do not exist on this cluster**. kubelet v1.36.4 exposes `kubelet_volume_metric_collection_duration_seconds` but no volume stats for any node (`kubectl get --raw /api/v1/nodes/<node>/proxy/metrics | grep volume_stats` is empty, zero series in Prometheus). The per-PVC rules in `monitoring/controllers/home/prune-alerts.yaml` are therefore correct-but-inert; live coverage is the node-filesystem alert, because every local-path PV lives on siriussec's `/`.
- **Per-PVC usage is not measurable on this cluster, and no alert pretends otherwise.** `kubelet_volume_stats_*` was an ALPHA metric set served from kubelet's `/metrics/volumes` endpoint; on kubelet v1.36.4 that endpoint returns **404 on all three nodes** (`/metrics`, `/metrics/probes`, `/metrics/cadvisor`, `/metrics/resource` all return 200) and `/metrics` carries no volume-stats series — the upstream loss in kubelet 1.34 (kubernetes/kubernetes#133847, fix #133890), not a hostPath quirk. There is therefore no scrape config that can produce those series; re-deriving them would need a new exporter parsing kubelet's `/stats/summary` JSON (new Deployment + `nodes/stats` RBAC). The old `RunnerDindPvcHighWatermark` / `RunnerDindPvcCritical` rules were deleted for selecting a metric with no producer, and replaced by runner-scoped filesystem rules — see below.
**Alerts** (`PrometheusRule monitoring/forgejo-prune`, label `release: kube-prometheus-stack`): `ForgejoPruneCronJobStale` (last success > 26 h, or the series absent), `ForgejoPruneJobFailed` (`kube_job_status_failed` for `forgejo-runner-prune-*` > 0 — `kube_job_failed` no longer exists), `NodeFilesystemFillingUp` / `NodeFilesystemCritical` (root fs > 85 % / > 92 % per node, joined to the hostname via `node_uname_info`), plus `RunnerDindPvcHighWatermark` / `RunnerDindPvcCritical` (85 % / 95 %, inert as above). Alertmanager is disabled in this stack, so they surface in Prometheus → Alerts and Grafana → Alerting, not as pages.
**Alerts** (`PrometheusRule monitoring/forgejo-prune`, label `release: kube-prometheus-stack`): `ForgejoPruneCronJobStale` (last success > 26 h, or the series absent), `ForgejoPruneJobFailed` (`kube_job_status_failed` for `forgejo-runner-prune-*` > 0 — `kube_job_failed` no longer exists), `NodeFilesystemFillingUp` / `NodeFilesystemCritical` (root fs > 85 % / > 92 % per node, joined to the hostname via `node_uname_info`), plus the node-filesystem guards that replaced them: `RunnerDindDiskHighWatermark` / `RunnerDindDiskCritical` (root fs > 80 % / > 90 % on nodes that run a `forgejo-runner` pod — joined node → `node_uname_info.nodename` → `kube_pod_info.node`, rpi excluded), and `RpiDindDataRootFillingUp` (group `dind-disk-cap`, rpi root fs > 70 %, because it carries 240 GiB of dind PVCs on a 917 G disk). The dind data-root is a plain directory under `/opt/local-path-provisioner` on that filesystem, so filesystem fill is the only honest per-runner signal. Alertmanager is disabled in this stack, so they surface in Prometheus → Alerts and Grafana → Alerting, not as pages.
---

View file

@ -213,11 +213,14 @@ deploying another exporter.
kube-state-metrics see only the runner pod. Per-job CPU/mem/disk on rpi is
therefore unavailable — the board shows rpi's root filesystem instead, because
that is where those containers write.
- **No per-PV usage.** local-path provisions `hostPath` PVs; kubelet publishes no
`kubelet_volume_stats_used_bytes` for hostPath volumes (on this cluster the only
`kubelet_volume_*` series are the collector-duration histograms). The dind PVC's
- **No per-PV usage.** kubelet 1.34+ no longer exports the alpha
`kubelet_volume_stats_*` metrics: its `/metrics/volumes` endpoint 404s on every
node here (kubelet v1.36.4, upstream kubernetes/kubernetes#133847), so there is
nothing to chart per PV and no scrape config would change that. The dind PVC's
20Gi is shown as *requested capacity* next to siriussec's root-filesystem usage,
which is the number that actually produced the DiskPressure evictions.
which is the number that actually produced the DiskPressure evictions — and the
same filesystem is what `RunnerDindDiskHighWatermark` / `RunnerDindDiskCritical`
alert on, scoped to nodes that run a runner.
- **Single-instance Postgres.** Both clusters run `instances: 1`, so replication
lag, streaming replicas and in-recovery are structurally zero. The panels show
the zero and say why instead of being hidden.

View file

@ -219,10 +219,12 @@ runner liveness as *Forgejo* sees it (`action_runner.last_online`), queue depth
plain host containers with no pod identity. cAdvisor/kube-state-metrics see only the runner
pod itself. There is no per-job CPU/mem/disk on rpi and there cannot be one without changing
the runner to dind — which this board deliberately does not propose.
- **Per-PV bytes for the dind PVC.** local-path PVs are `hostPath`, and kubelet publishes no
`kubelet_volume_stats_*` for hostPath volumes (verified: the only `kubelet_volume_*` series on
this cluster are the collector-duration histograms). The usable proxy is siriussec's root
filesystem usage plus the PVC's requested size, both on this row.
- **Per-PV bytes for the dind PVC.** kubelet 1.34+ no longer exports the alpha
`kubelet_volume_stats_*` set at all: its `/metrics/volumes` endpoint returns 404 on every node
here (kubelet v1.36.4; upstream kubernetes/kubernetes#133847), so no scrape config can produce
those series and it is not a hostPath quirk. The usable proxy is the runner node's root
filesystem usage plus the PVC's requested size, both on this row — and the `RunnerDindDisk*`
alerts watch that same filesystem, scoped to nodes that run a runner.
""", {"h": 7, "w": 24, "x": 0, "y": 33}),
]
@ -364,10 +366,10 @@ workloads = [
desc="Root filesystem per node — the local-path PVs, the dind data-root and the Pi's host-docker job containers all land on these."),
note("Known unknowns on this board", """\
- **PVC usage is not charted, only requested capacity.** local-path provisions `hostPath` PVs and kubelet
publishes no `kubelet_volume_stats_used_bytes` for them (this cluster only emits the
`kubelet_volume_metric_collection_duration_seconds` histograms). Node filesystem usage is the honest
proxy for "how full is the disk these PVs live on".
- **PVC usage is not charted, only requested capacity.** kubelet 1.34+ dropped the alpha
`kubelet_volume_stats_*` metrics (its `/metrics/volumes` endpoint 404s on every node here), so
there is nothing to chart per PV. Node filesystem usage is the honest proxy for "how full is
the disk these PVs live on".
- **Namespaces are not filtered.** With this few workloads an unfiltered board is more useful than a
variable that hides the one namespace you needed to see.
- **No Alertmanager.** Alerts from `PrometheusRule` objects are visible in Prometheus /alerts and in

View file

@ -1201,7 +1201,7 @@ data:
"showLineNumbers": false,
"showMiniMap": false
},
"content": "**Measured:** runner Deployments (kube-state-metrics), runner pods CPU/mem/net/restarts (cAdvisor),\nrunner liveness as *Forgejo* sees it (`action_runner.last_online`), queue depth and job outcomes\n(`action_run_job` via the CNPG exporter), and the host filesystems that CI fills (node-exporter).\n\n**Not measurable \u2014 by design, not by omission:**\n\n- **Per-job breakdown on the arm64 runner.** `forgejo-runner-arm64` and\n `forgejo-runner-deploy-arm64` drive the **host** Docker socket (gid 984), so their jobs are\n plain host containers with no pod identity. cAdvisor/kube-state-metrics see only the runner\n pod itself. There is no per-job CPU/mem/disk on rpi and there cannot be one without changing\n the runner to dind \u2014 which this board deliberately does not propose.\n- **Per-PV bytes for the dind PVC.** local-path PVs are `hostPath`, and kubelet publishes no\n `kubelet_volume_stats_*` for hostPath volumes (verified: the only `kubelet_volume_*` series on\n this cluster are the collector-duration histograms). The usable proxy is siriussec's root\n filesystem usage plus the PVC's requested size, both on this row.\n"
"content": "**Measured:** runner Deployments (kube-state-metrics), runner pods CPU/mem/net/restarts (cAdvisor),\nrunner liveness as *Forgejo* sees it (`action_runner.last_online`), queue depth and job outcomes\n(`action_run_job` via the CNPG exporter), and the host filesystems that CI fills (node-exporter).\n\n**Not measurable \u2014 by design, not by omission:**\n\n- **Per-job breakdown on the arm64 runner.** `forgejo-runner-arm64` and\n `forgejo-runner-deploy-arm64` drive the **host** Docker socket (gid 984), so their jobs are\n plain host containers with no pod identity. cAdvisor/kube-state-metrics see only the runner\n pod itself. There is no per-job CPU/mem/disk on rpi and there cannot be one without changing\n the runner to dind \u2014 which this board deliberately does not propose.\n- **Per-PV bytes for the dind PVC.** kubelet 1.34+ no longer exports the alpha\n `kubelet_volume_stats_*` set at all: its `/metrics/volumes` endpoint returns 404 on every node\n here (kubelet v1.36.4; upstream kubernetes/kubernetes#133847), so no scrape config can produce\n those series and it is not a hostPath quirk. The usable proxy is the runner node's root\n filesystem usage plus the PVC's requested size, both on this row \u2014 and the `RunnerDindDisk*`\n alerts watch that same filesystem, scoped to nodes that run a runner.\n"
}
}
]

View file

@ -1141,7 +1141,7 @@ data:
"showLineNumbers": false,
"showMiniMap": false
},
"content": "- **PVC usage is not charted, only requested capacity.** local-path provisions `hostPath` PVs and kubelet\n publishes no `kubelet_volume_stats_used_bytes` for them (this cluster only emits the\n `kubelet_volume_metric_collection_duration_seconds` histograms). Node filesystem usage is the honest\n proxy for \"how full is the disk these PVs live on\".\n- **Namespaces are not filtered.** With this few workloads an unfiltered board is more useful than a\n variable that hides the one namespace you needed to see.\n- **No Alertmanager.** Alerts from `PrometheusRule` objects are visible in Prometheus /alerts and in\n Grafana \u2192 Alerting, but nothing pages.\n"
"content": "- **PVC usage is not charted, only requested capacity.** kubelet 1.34+ dropped the alpha\n `kubelet_volume_stats_*` metrics (its `/metrics/volumes` endpoint 404s on every node here), so\n there is nothing to chart per PV. Node filesystem usage is the honest proxy for \"how full is\n the disk these PVs live on\".\n- **Namespaces are not filtered.** With this few workloads an unfiltered board is more useful than a\n variable that hides the one namespace you needed to see.\n- **No Alertmanager.** Alerts from `PrometheusRule` objects are visible in Prometheus /alerts and in\n Grafana \u2192 Alerting, but nothing pages.\n"
}
}
]

View file

@ -8,21 +8,31 @@
# What is measurable here:
# - node filesystem utilisation per node (node-exporter, all three nodes);
# on siriussec the local-path PVs — including the runner's dind data-root —
# live on `/`, so this is the DiskPressure precursor and the PVC watchdog
# in one series.
# live on `/`, so this is the DiskPressure precursor and the closest thing
# to a PVC watchdog this cluster can have (runner-scoped rules below).
# - CronJob last-success timestamp and Job failure counters
# (kube-state-metrics).
#
# What is NOT measurable here: kubelet_volume_stats_* does not exist on this
# cluster. Verified 2026-10-27: kubelet v1.36.4 exposes
# kubelet_volume_metric_collection_duration_seconds but no
# kubelet_volume_stats_used_bytes / _capacity_bytes on any node
# (`kubectl get --raw /api/v1/nodes/<node>/proxy/metrics | grep volume_stats`
# is empty, and Prometheus has zero series). So the per-PVC rules below are
# written against those metric names but stay inert until a kubelet exports
# them; the node-filesystem rules are the live coverage. Per-PVC and per-Docker
# -volume sizes are printed by the prune job every night
# (`docker system df -v`), which is the record of growth.
# What is NOT measurable here — per-PVC bytes. kubelet_volume_stats_* was an
# ALPHA metric set served from kubelet's /metrics/volumes endpoint; that
# endpoint is gone in this cluster's kubelet. Verified 2026-10-27 on kubelet
# v1.36.4: `https://<node>:10250/metrics/volumes` returns **404 on all three
# nodes** (10.10.0.2 / 10.10.0.1 / 10.10.0.5) while /metrics, /metrics/probes,
# /metrics/cadvisor and /metrics/resource return 200, `/metrics` contains no
# kubelet_volume_stats_* series at all, and Prometheus has zero series for
# either name. This is the upstream loss of the alpha volume-stats metrics in
# kubelet 1.34 (kubernetes/kubernetes#133847, regression fix #133890), not a
# hostPath/PVC-type quirk and not something a scrape config can bring back:
# there is no endpoint left to scrape, and re-deriving it would mean a new
# exporter parsing kubelet's /stats/summary JSON (new Deployment + nodes/stats
# RBAC) — out of proportion for a three-node lab. So: no alert here selects a
# metric that does not exist. Coverage is the node filesystem that actually
# holds the data: `RunnerDindDisk*` below (runner-scoped, 80/90 %, every node
# running a runner except rpi), `RpiDindDataRootFillingUp` in group
# `dind-disk-cap` (rpi, 70 %, because its 240 GiB of dind PVCs sit on a 917 G
# disk) and the generic `disk-capacity` group (85/92 %). Per-PVC and
# per-Docker-volume sizes are still printed by the prune job every night
# (`docker system df -v`) — that output is the record of growth.
#
# Alertmanager is disabled in this stack (monitoring card), so these surface in
# Prometheus → Alerts and Grafana → Alerting. No external receiver is added.
@ -81,60 +91,102 @@ spec:
not reachable over the exec API, so that daemon is growing
unpruned. One retry is allowed by backoffLimit; persistent
failures need the RBAC or the pod checked.
# Per-PVC rules: correct expressions, currently inert (see the header —
# this cluster's kubelet exports no kubelet_volume_stats_* series). They
# start working the day that comes back, and they cost nothing until
# then. Coverage today is NodeFilesystemFillingUp on siriussec, where
# every local-path PV physically lives.
- alert: RunnerDindPvcHighWatermark
# Runner-scoped filesystem rules: this is the honest replacement for the
# old per-PVC pair (kubelet_volume_stats_* has no producer — header).
# They measure the filesystem that actually backs the dind data-root, on
# the nodes that actually run a forgejo-runner pod. On siriussec that is
# /opt/local-path-provisioner/pvc-*_forgejo_forgejo-runner-amd64 (dind's
# /var/lib/docker) on the root ext4.
# Scoping by *pod* rather than by PVC name is deliberate: the PVCs are
# shared-filesystem consumers, arm64 dind PVCs are covered the moment
# their runner pod is scheduled, and nodes that run no runner (linode) do
# not duplicate the generic disk-capacity group.
# rpi is deliberately excluded (nodename!="rpi"): it carries 240 GiB of
# dind PVCs on a 917 G disk, so 80 % (~734 G) would be far too late to run
# the prune job. Group `dind-disk-cap` holds its tighter 70 % cap
# (RpiDindDataRootFillingUp). Two rules, two disks, no double page.
# Thresholds here are 5 points tighter than NodeFilesystemFillingUp /
# Critical so CI fill is reported as CI fill, with the runner runbook.
- alert: RunnerDindDiskHighWatermark
expr: |
max by (namespace, persistentvolumeclaim) (
kubelet_volume_stats_used_bytes{namespace="forgejo", persistentvolumeclaim=~"forgejo-runner-.*"}
)
/
max by (namespace, persistentvolumeclaim) (
kubelet_volume_stats_capacity_bytes{namespace="forgejo", persistentvolumeclaim=~"forgejo-runner-.*"}
) > 0.85
for: 15m
(
(
(
1 - (
node_filesystem_avail_bytes{mountpoint="/", fstype=~"ext4|xfs|btrfs"}
/
node_filesystem_size_bytes{mountpoint="/", fstype=~"ext4|xfs|btrfs"}
)
) * on (instance) group_left (nodename) node_uname_info{nodename!="rpi"}
)
and on (nodename)
label_replace(
max by (node) (kube_pod_info{namespace="forgejo", pod=~"forgejo-runner-.*"}),
"nodename", "$1", "node", "(.+)"
)
) > 0.80
for: 30m
labels:
severity: warning
annotations:
summary: >-
dind PVC {{ $labels.persistentvolumeclaim }} is over 85% full
{{ $labels.nodename }} is {{ $value | humanizePercentage }} full —
the filesystem carrying this node's Forgejo runner dind data-root
description: >-
The image/build-cache/volume footprint on this runner's dind
daemon is approaching the 20Gi PVC. Inspect it with
`kubectl -n forgejo exec <runner-pod> -c dind -- docker system df -v`;
the nightly prune caps build cache but never deletes named
volumes.
- alert: RunnerDindPvcCritical
A forgejo-runner pod runs on {{ $labels.nodename }}, and the dind
data-root lives under /opt/local-path-provisioner on this node's
root filesystem, so CI images, build cache and named volumes fill
the same disk as Forgejo/Postgres (siriussec) or the host Docker
daemon (rpi). Per-PVC bytes cannot be measured here — kubelet 1.34+
no longer exports kubelet_volume_stats_* and /metrics/volumes is
404 — so this node-level rule is the guard. Inspect the offenders:
`kubectl -n forgejo exec <runner-pod> -c dind -- docker system df -v`
and `du -sh /opt/local-path-provisioner/pvc-*` on the node, then let
the nightly prune reclaim (or force it: kubectl -n forgejo create job
--from=cronjob/forgejo-runner-prune prune-manual-$(date +%s)).
- alert: RunnerDindDiskCritical
expr: |
max by (namespace, persistentvolumeclaim) (
kubelet_volume_stats_used_bytes{namespace="forgejo", persistentvolumeclaim=~"forgejo-runner-.*"}
)
/
max by (namespace, persistentvolumeclaim) (
kubelet_volume_stats_capacity_bytes{namespace="forgejo", persistentvolumeclaim=~"forgejo-runner-.*"}
) > 0.95
for: 5m
(
(
(
1 - (
node_filesystem_avail_bytes{mountpoint="/", fstype=~"ext4|xfs|btrfs"}
/
node_filesystem_size_bytes{mountpoint="/", fstype=~"ext4|xfs|btrfs"}
)
) * on (instance) group_left (nodename) node_uname_info{nodename!="rpi"}
)
and on (nodename)
label_replace(
max by (node) (kube_pod_info{namespace="forgejo", pod=~"forgejo-runner-.*"}),
"nodename", "$1", "node", "(.+)"
)
) > 0.90
for: 10m
labels:
severity: critical
annotations:
summary: >-
dind PVC {{ $labels.persistentvolumeclaim }} is over 95% full
{{ $labels.nodename }} is {{ $value | humanizePercentage }} full —
runner builds will fail with ENOSPC
description: >-
Builds will start failing with ENOSPC. Scale the runner to 0,
raise the PVC, or clear the dind data-root deliberately (see the
DiskPressure runbook in the home-k8s skill) — do not wipe it
while the runner pod is up.
DiskPressure is imminent on a node running CI: kubelet starts
evicting (Forgejo + pg-1 went Pending on siriussec this way) and
dind builds fail with "no space left on device". Act now: scale the
runner to 0 (`kubectl -n forgejo scale deploy/<runner> --replicas=0`),
force the prune, and only then clear the dind data-root by hand
(`/opt/local-path-provisioner/pvc-*_forgejo_forgejo-runner-*/` on
the node) — never wipe it while the runner pod is up. The 20Gi PVC
request does not cap the directory: local-path PVs are plain
directories, so the filesystem fills first.
- name: dind-disk-cap
rules:
# Pi-specific cap, added with the arm64 dind cutover (kanban
# t_0da0a1cc). The two arm64 runners now hold 240 GiB of dind PVCs
# (200Gi shared + 40Gi deploy) on rpi's single root filesystem, which
# is the same disk the kubelet lives on. A static hostPath PV does NOT
# enforce its claim, and the `RunnerDindPvc*` rules cannot fire for it
# (no kubelet_volume_stats_* series on this cluster), so this node
# enforce its claim, and per-PVC usage cannot be alerted on at all
# (kubelet 1.34+ exports no kubelet_volume_stats_*, header), so this node
# filesystem rule is the real growth cap: 70 % of 917 G leaves ~275 G,
# i.e. reachable while there is still room to run the prune job.
# `NodeFilesystemFillingUp` below stays at 85 % as the backstop.