#!/bin/sh # Keep the host's writeback backlog bounded so an etcd WAL fdatasync does not # wait for gigabytes of dind writeback. Idempotent: rewrites only on drift. # # Deliberately NOT done here: per-cgroup io.latency / io.max on the dind pod. # io.latency only throttles *peers of the same parent* (cgroup-v2 doc, and # block/blk-iolatency.c: a miss is recorded in the missing group's parent # child_lat), and kubelet puts every pod in its own slice, so an etcd target # can never throttle the dind pod - measured on 2026-10-26: dind depth stayed # `max` and the stall count did not move. See README.md in the repo. set -u DB="${DIRTY_BYTES:-67108864}" DBG="${DIRTY_BACKGROUND_BYTES:-16777216}" log() { echo "$(date -u +%FT%TZ) $*"; } log "start dirty_bytes=${DB} dirty_background_bytes=${DBG}" while true; do cur_bg="$(cat /host/proc/sys/vm/dirty_background_bytes 2>/dev/null || echo read-error)" # dirty_background_bytes must be written before dirty_bytes: writing # dirty_bytes zeroes dirty_ratio, and a nonzero dirty_background_bytes keeps # dirty_background_ratio out of play. if [ "${cur_bg}" != "${DBG}" ]; then if echo "${DBG}" > /host/proc/sys/vm/dirty_background_bytes 2>/dev/null; then log "applied vm.dirty_background_bytes=${DBG} (was ${cur_bg})" else log "FAILED to write vm.dirty_background_bytes" fi fi cur_db="$(cat /host/proc/sys/vm/dirty_bytes 2>/dev/null || echo read-error)" if [ "${cur_db}" != "${DB}" ]; then if echo "${DB}" > /host/proc/sys/vm/dirty_bytes 2>/dev/null; then log "applied vm.dirty_bytes=${DB} (was ${cur_db})" else log "FAILED to write vm.dirty_bytes" fi fi sleep 30 done